Difference between revisions of "St. Joes Stockton TAVR"
From TheInterWiki
| Line 1: | Line 1: | ||
| + | |||
| + | {{Note|OR nurses will open light covers and dressing supplies from their stock.}} | ||
==TAVR Pack list== | ==TAVR Pack list== | ||
| Line 30: | Line 32: | ||
*6fr AngioSeal | *6fr AngioSeal | ||
| + | ==Edwards== | ||
===Edwards pacer supplies=== | ===Edwards pacer supplies=== | ||
| Line 44: | Line 47: | ||
*30cc syringe | *30cc syringe | ||
| − | === | + | ==Medtronic== |
| + | ====Open==== | ||
| + | *Confida wire | ||
| + | *Alligator clips | ||
| + | |||
====Standby==== | ====Standby==== | ||
*Pacer setup | *Pacer setup | ||
*Venous sheath and lines | *Venous sheath and lines | ||
| − | |||
| − | |||
| − | |||
==Procedure== | ==Procedure== | ||
Revision as of 13:49, 10 June 2026
Note: OR nurses will open light covers and dressing supplies from their stock.
TAVR Pack list
Stock Room
- Basic Pack (Large table cover)
- Marquis Blue Stopcock x2
- 2 grey needles
- U/S Probe Cover
- Acist touch kit long pack
- Micropuncture Introducer Set x2
- Transducer
- Amplatz Extra Stiff Wire Guide .035 260 -Edwards
- Confida- Medtronic or Mahadevan
- 3-8 Green Glove 2-7 Purple Gloves 3-7-½ PI Glove 2-7 PI Glove1-7 ½ Biogel Glove
Room 1
- 6 FR Terumo Pinnacle Ref RSS602 x2
- 8 FR Terumo Pinnacle Ref RSS802 x1
- .035 J Wire 145
- .035 / Wire 260 cm X1
- .035 LLT Guide wire 145CM X1
- Lunderquist Extra Stiff Wire Guide double curve 260CM X1 -not Punnam Ali
- 6 FR Per Close Proglide x2
- 60CC Syringe X2 (2-extra for Buhari)
- 24" tubing
- 48" tubing
- 8 - 10CC Syringes
Supply cart by break room
- Mynx Perclose for Mahadevan
- 6fr AngioSeal
Edwards
Edwards pacer supplies
- Remington pacer cables
- Repositioning Sleeve
- 5FR (197MM) Pacel pacing catheter
- 2-3 Blue Sterile Bowls (Disposable)
- 6 FR Terumo Pinnacle REF. R55602 X1
- 2 24" Tubing
Edwards setup
- 20ml contrast to setup table for mix
- 2x60cc syringes
- 30cc syringe
Medtronic
Open
- Confida wire
- Alligator clips
Standby
- Pacer setup
- Venous sheath and lines
Procedure
- Full OR prep, but standard CCL drape.
- RN opens venous extension.
- Drs get access and help themselves.
- 6fr to dilate
- 6fr venous
- Pre close
- 8fr sheath arterial
- Pigtail
- Crossing catheter
- Vein access
- Pacer
- Lunderquist -> sheath
- Lund out
- Position pigtail
- Cross valve
- 260j
- Pigtail across valve
- Amplatz in
- Load valve
- Advance valve on balloon
- Deploy
- Fluoro Save!
- Echo
- Remove system
- Pigtail for gradient
- Short j's
- Perclose
- Angioseal for 6fr artery
- Mynx for vein
- Cleanup
Notes
Ali / Punnam
- 8fr for vein
- Amp ss for big sheath no lunderquist
- 14fr. sheath dilator first, not 16fr
- Confida
- Extra Perclose for L art.
- Manual pressure for vein
- No glue