Difference between revisions of "UCD Micra/Aveir"
From TheInterWiki
(Created page with "Miera/Aveir #EP pack #Probe cover #Micropuncture #8F non locking sheath #Two 3mL transducers for Micra, Four 3mL transducers for Aveir a. No 3 way stop cocks for Aveir cases...") |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | ==Open== | |
#EP pack | #EP pack | ||
#Probe cover | #Probe cover | ||
Line 5: | Line 5: | ||
#8F non locking sheath | #8F non locking sheath | ||
#Two 3mL transducers for Micra, Four 3mL transducers for Aveir | #Two 3mL transducers for Micra, Four 3mL transducers for Aveir | ||
− | + | #*No 3 way stop cocks for Aveir cases | |
− | + | #Amplatz super stiff 0.35, 180cm | |
− | Amplatz super stiff 0.35, 180cm | + | #Dilator set |
− | + | #Two 60mL syringes | |
− | + | *20cc syringe | |
− | + | #Contrast | |
− | + | #0-silk suture | |
− | + | #Steristrips | |
− | + | ||
+ | ==Standby== | ||
+ | #Perclose × 2 | ||
+ | |||
+ | |||
+ | ==Aveir steps== | ||
+ | #US guided access with micropuncture | ||
+ | #Sheath wire | ||
+ | #8fr. Dilator | ||
+ | #Preclose x2 | ||
+ | #Amplatz SS loaded through second Perclose | ||
+ | #Dilate with 12, 16, 22 dilators | ||
+ | #Attach drip A to introducer sheath and insert | ||
+ | #Attach B, C, D drip lines to delivery system | ||
+ | #*Adjust drips and check for air | ||
+ | #Attach 20cc syringe with straight contrast to side port of C drip line | ||
+ | #Deploy device | ||
+ | #Close with Preclosed sutures | ||
+ | #Close skin with [[Sample Setup Page (Woggle)|Woggle]] using 0-Prolene | ||
+ | #Dress with gauze and Tegaderm |
Latest revision as of 16:28, 25 October 2023
Open
- EP pack
- Probe cover
- Micropuncture
- 8F non locking sheath
- Two 3mL transducers for Micra, Four 3mL transducers for Aveir
- No 3 way stop cocks for Aveir cases
- Amplatz super stiff 0.35, 180cm
- Dilator set
- Two 60mL syringes
- 20cc syringe
- Contrast
- 0-silk suture
- Steristrips
Standby
- Perclose × 2
Aveir steps
- US guided access with micropuncture
- Sheath wire
- 8fr. Dilator
- Preclose x2
- Amplatz SS loaded through second Perclose
- Dilate with 12, 16, 22 dilators
- Attach drip A to introducer sheath and insert
- Attach B, C, D drip lines to delivery system
- Adjust drips and check for air
- Attach 20cc syringe with straight contrast to side port of C drip line
- Deploy device
- Close with Preclosed sutures
- Close skin with Woggle using 0-Prolene
- Dress with gauze and Tegaderm