==Open== | ==Open== | ||
+ | |||
+ | *EP Pack | ||
+ | *Flexcath | ||
+ | *28mm Arctic Advance | ||
*Probe Cover | *Probe Cover | ||
− | *Ice Cover - Shockwave | + | *2 - Ice Cover - Shockwave |
*Copilot | *Copilot | ||
*Manifold + dump bag | *Manifold + dump bag | ||
*Smart Ablate Tubing | *Smart Ablate Tubing | ||
− | |||
*Micropuncture | *Micropuncture | ||
+ | *20ml syringes 2-4 | ||
+ | *A-line set | ||
+ | *Pressure transducer kit x3 | ||
*7F locking | *7F locking | ||
*8F locking | *8F locking | ||
− | *8.5 | + | *8.5 Non-locking |
− | |||
− | |||
*6fr CRD 2 quad | *6fr CRD 2 quad | ||
− | + | ||
Line 23: | Line 27: | ||
!Munir | !Munir | ||
|- | |- | ||
− | | | + | |'''Stockroom''' |
− | | | + | | |
| | | | ||
| | | | ||
|- | |- | ||
− | | | + | |Versacross D0 |
− | | | + | |Versacross D1 |
| | | | ||
| | | | ||
|- | |- | ||
− | | | + | |Soundstar 10Fr |
+ | |Soundstar 8Fr | ||
+ | | | ||
| | | | ||
+ | |- | ||
+ | |DecaNav D | ||
+ | |DecaNav F | ||
| | | | ||
| | | | ||
|- | |- | ||
− | |||
− | |||
| | | | ||
| | | | ||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
|- | |- | ||
− | | | + | |'''Lab''' |
− | | | + | | |
| | | | ||
| | | | ||
|- | |- | ||
|Octaray D 2-2-2 | |Octaray D 2-2-2 | ||
− | |Octaray F | + | |Octaray F 3-3-3 |
| | | | ||
| | | | ||
|- | |- | ||
|Dynamic XT steerable quad | |Dynamic XT steerable quad | ||
+ | |CRD 2 Quad | ||
| | | | ||
+ | | | ||
+ | |- | ||
+ | |Achieve 20mm | ||
+ | |Achieve 15mm | ||
| | | | ||
| | | | ||
|- | |- | ||
− | |Standby | + | |Long 11Fr |
− | |colspan = 3 |If needed for touch up post cryo or for redo afib. | + | |Long 9Fr |
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |14fr non-locking | ||
+ | |Zero Gravity drape | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |'''Standby''' | ||
+ | |colspan = 3 |''If needed for touch up post cryo or for redo afib''. | ||
|- | |- | ||
|Smart touch thermocool STSF DF | |Smart touch thermocool STSF DF | ||
Line 74: | Line 98: | ||
|Perclose x1 | |Perclose x1 | ||
Vascade x3 | Vascade x3 | ||
+ | | | ||
| | | | ||
|} | |} | ||
Line 86: | Line 111: | ||
*Quad cable x 2 | *Quad cable x 2 | ||
*Abalator cable | *Abalator cable | ||
+ | |||
+ | ==Procedure (tech)== | ||
+ | ===Pre=== | ||
+ | Read [[UCD EP Role]] for pre and post procedural steps. | ||
+ | *Include CMAP when patching for phrenic pacing | ||
+ | **Cable located in C block #31-32 | ||
+ | **Attach alligator clips to patches | ||
+ | *Set up pressure lines | ||
+ | **Double spike Hep saline bag under pressure | ||
+ | **Flush and connect blue pressure to transducer closest to patient on rack (P1) | ||
+ | *Zero A-line | ||
+ | *Assist with hooking up | ||
+ | **Vascular US | ||
+ | **EP cables | ||
+ | ***Achieve to pin block Blue 1-10 | ||
+ | ***Deca nav to Deca | ||
+ | ***His Quad to Quad B (OK to unplug pin block quad plug) | ||
+ | |||
+ | ===During case=== | ||
+ | *Open ablation window on live screen | ||
+ | **right click in ablation window to change ablator. | ||
+ | **Check dial for correct ablator. | ||
+ | *Check that ablation switch behind ablation consoles is set to "Cryo" | ||
+ | *Physician will place catheters and access LA. | ||
+ | *Be ready for backup pacing post cardioversion (usually HisD) | ||
+ | *Measure LA pressure | ||
+ | *Measure conduction intervals | ||
+ | *Once Cryo ballon is in LA and ablation starts do the following: | ||
+ | **Save and label freeze frame of fluoro with location of freeze and ablation number ex: "LUPV Cryo #1" copy this text and save | ||
+ | **Monitor ablation sequence | ||
+ | **After ablation ends, record ablation data including copied text to Ablation End log entry comment section ex: "LUPV Cryo #1 180sec -45C" | ||
+ | ***If esophagus temp is affected, record this temp also "23C esoph" | ||
+ | **EP study is conducted during Cryo ablation phase of procedure | ||
+ | ***Atrial Wenckebach, Atrial ERP, and VERP | ||
+ | **When phrenic nerve is involved. Prepare to pace CMAP | ||
+ | ***Channel 4 800msec, 25mA | ||
+ | ***When freeze is initiated, come on pacing as temp passes 0C | ||
+ | ***When thawing, come off pacing as temp passes 0C | ||
+ | |||
+ | ==Procedure (scrub)== | ||
+ | ===Pre=== | ||
+ | *Label pressure lines | ||
+ | **Blue - Transseptal line connected to P1. Swapped to manifold during cryo ablation. | ||
+ | **Yellow - not transduced connected to flex cath sheath. | ||
+ | **No color - used for Octaray drip. Keep manifold on table. | ||
+ | **A-line setup. Pre labeled red. Connects to sheath for act draws. | ||
+ | *Setup manifold | ||
+ | **Cap 2 middle ports for Srivasta. No dump bag | ||
+ | **Position 1 connects to blue pressure line. | ||
+ | *Position 4 pass off spike for pressurized saline. |
Latest revision as of 20:34, 26 October 2023
Open
- EP Pack
- Flexcath
- 28mm Arctic Advance
- Probe Cover
- 2 - Ice Cover - Shockwave
- Copilot
- Manifold + dump bag
- Smart Ablate Tubing
- Micropuncture
- 20ml syringes 2-4
- A-line set
- Pressure transducer kit x3
- 7F locking
- 8F locking
- 8.5 Non-locking
- 6fr CRD 2 quad
Pezeshkian | Srivatsa | Cortez | Munir |
---|---|---|---|
Stockroom | |||
Versacross D0 | Versacross D1 | ||
Soundstar 10Fr | Soundstar 8Fr | ||
DecaNav D | DecaNav F | ||
Lab | |||
Octaray D 2-2-2 | Octaray F 3-3-3 | ||
Dynamic XT steerable quad | CRD 2 Quad | ||
Achieve 20mm | Achieve 15mm | ||
Long 11Fr | Long 9Fr | ||
14fr non-locking | Zero Gravity drape | ||
Standby | If needed for touch up post cryo or for redo afib. | ||
Smart touch thermocool STSF DF | Smart touch thermocool ST FJ | ||
Perclose x1
Vascade x3 |
Cables
- Achieve cable
- Electrical umbilical cable
- Coaxial umbilical cable
- DecNav cable
- Pentaray cable
- Quad cable x 2
- Abalator cable
Procedure (tech)
Pre
Read UCD EP Role for pre and post procedural steps.
- Include CMAP when patching for phrenic pacing
- Cable located in C block #31-32
- Attach alligator clips to patches
- Set up pressure lines
- Double spike Hep saline bag under pressure
- Flush and connect blue pressure to transducer closest to patient on rack (P1)
- Zero A-line
- Assist with hooking up
- Vascular US
- EP cables
- Achieve to pin block Blue 1-10
- Deca nav to Deca
- His Quad to Quad B (OK to unplug pin block quad plug)
During case
- Open ablation window on live screen
- right click in ablation window to change ablator.
- Check dial for correct ablator.
- Check that ablation switch behind ablation consoles is set to "Cryo"
- Physician will place catheters and access LA.
- Be ready for backup pacing post cardioversion (usually HisD)
- Measure LA pressure
- Measure conduction intervals
- Once Cryo ballon is in LA and ablation starts do the following:
- Save and label freeze frame of fluoro with location of freeze and ablation number ex: "LUPV Cryo #1" copy this text and save
- Monitor ablation sequence
- After ablation ends, record ablation data including copied text to Ablation End log entry comment section ex: "LUPV Cryo #1 180sec -45C"
- If esophagus temp is affected, record this temp also "23C esoph"
- EP study is conducted during Cryo ablation phase of procedure
- Atrial Wenckebach, Atrial ERP, and VERP
- When phrenic nerve is involved. Prepare to pace CMAP
- Channel 4 800msec, 25mA
- When freeze is initiated, come on pacing as temp passes 0C
- When thawing, come off pacing as temp passes 0C
Procedure (scrub)
Pre
- Label pressure lines
- Blue - Transseptal line connected to P1. Swapped to manifold during cryo ablation.
- Yellow - not transduced connected to flex cath sheath.
- No color - used for Octaray drip. Keep manifold on table.
- A-line setup. Pre labeled red. Connects to sheath for act draws.
- Setup manifold
- Cap 2 middle ports for Srivasta. No dump bag
- Position 1 connects to blue pressure line.
- Position 4 pass off spike for pressurized saline.