Difference between revisions of "St joes carotid"

From TheInterWiki
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
Sheath: 6 Fr. Shuttle 90 cm
+
==Open:==
Merit touhy for shuttle (Raina)
+
 
Catheter: Headhunter (H1) 100 or V-tek 100cm 125 For Dr Emani
+
===Sheath:===
Wires:  
+
*6 Fr. Shuttle 90 cm
 +
**Merit touhy for shuttle (Raina)
 +
===Catheter:===
 +
*Headhunter (H1) 100 or  
 +
*V-tek 100cm 125 For Dr Emani
 +
===Wires:===
 
*.035" x 260 Angled Glidewire
 
*.035" x 260 Angled Glidewire
 
*.035" x 260 Stiff Angled Glidewire
 
*.035" x 260 Stiff Angled Glidewire
Line 8: Line 13:
 
*Green torquer
 
*Green torquer
 
* Extra blue stopcock so you can prep both balloons
 
* Extra blue stopcock so you can prep both balloons
Thrombectomy Catheter: Pronto (in room)
+
===Thrombectomy Catheter:===
Distal Protection: 7.2mm Emboshield NAV (save introducer)
+
*Pronto (in room)
Balloons:  
+
 
 +
===Distal Protection:===
 +
*7.2mm Emboshield NAV (save introducer)
 +
 
 +
===Balloons:===
 
*4.0 × 40 × 135 Sterling RX,  
 
*4.0 × 40 × 135 Sterling RX,  
 
*5.0 × 20 x 135 Sterling RX  
 
*5.0 × 20 x 135 Sterling RX  
Line 16: Line 25:
 
*4.0 x 40 x 135 ViaTrac14,  
 
*4.0 x 40 x 135 ViaTrac14,  
 
*5.0 x 20 x 135 ViaTrac14
 
*5.0 x 20 x 135 ViaTrac14
Stent: 10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician
+
===Stent:===
 +
*10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician
  
 +
==Procedure:==
 
#Diagnostic shots
 
#Diagnostic shots
 
#Stiff glide in diagnostic catheter
 
#Stiff glide in diagnostic catheter

Latest revision as of 21:03, 14 August 2026

Open:

Sheath:

  • 6 Fr. Shuttle 90 cm
    • Merit touhy for shuttle (Raina)

Catheter:

  • Headhunter (H1) 100 or
  • V-tek 100cm 125 For Dr Emani

Wires:

  • .035" x 260 Angled Glidewire
  • .035" x 260 Stiff Angled Glidewire
  • .035" x 260 Rosen
  • Green torquer
  • Extra blue stopcock so you can prep both balloons

Thrombectomy Catheter:

  • Pronto (in room)

Distal Protection:

  • 7.2mm Emboshield NAV (save introducer)

Balloons:

  • 4.0 × 40 × 135 Sterling RX,
  • 5.0 × 20 x 135 Sterling RX

OR

  • 4.0 x 40 x 135 ViaTrac14,
  • 5.0 x 20 x 135 ViaTrac14

Stent:

  • 10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician

Procedure:

  1. Diagnostic shots
  2. Stiff glide in diagnostic catheter
  3. Stiff glide to eca
  4. Advance diagnostic catheter to eca
  5. Exchange stiff glide for Rosen
  6. Exchange sheath for shuttle
  7. Rosen out
  8. Prep all balloons and stent and stack
  9. Prep filter
  10. Filter in
  11. Pre balloon
  12. Stent
  13. Post balloon
  14. Retrieve filter


Drugs: Atropine, Dopamine, Neosynephrine NO conscious sedation Backup Retrieval sheath: EZ bent tip 1.40mm x 150 cm Squeaky toy in opposite hand of affected side.