Difference between revisions of "St joes carotid"

From TheInterWiki
Line 16: Line 16:
 
Stent: 10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician
 
Stent: 10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician
  
−
Diagnostic shots
+
#Diagnostic shots
−
Stiff glide in diagnostic catheter
+
#Stiff glide in diagnostic catheter
−
Stiff glide to eca
+
#Stiff glide to eca
−
Advance diagnostic catheter to eca
+
#Advance diagnostic catheter to eca
−
Exchange stiff glide for Rosen  
+
#Exchange stiff glide for Rosen  
−
Exchange sheath for shuttle
+
#Exchange sheath for shuttle
−
Rosen out
+
#Rosen out
−
Prep all balloons and stent and stack
+
#Prep all balloons and stent and stack
−
Prep filter
+
#Prep filter
−
Filter in
+
#Filter in
−
Pre balloon
+
#Pre balloon
−
Stent
+
#Stent
−
Post balloon
+
#Post balloon
−
Retrieve filter
+
#Retrieve filter
  
  
 
Drugs: Atropine, Dopamine, Neosynephrine
 
Drugs: Atropine, Dopamine, Neosynephrine
 
NO conscious sedation
 
NO conscious sedation
−
Retrieval sheath: EZ bent tip 1.40mm x 150 cm
+
Backup Retrieval sheath: EZ bent tip 1.40mm x 150 cm
 
Squeaky toy in opposite hand of affected side.
 
Squeaky toy in opposite hand of affected side.

Revision as of 20:08, 17 July 2026

Sheath: 6 Fr. Shuttle 90 cm Merit touhy for shuttle (Raina) Catheter: Headhunter (H1) 100 or V-tek 100cm 125 For Dr Emani Wires:

  • .035" x 260 Angled Glidewire
  • .035" x 260 Stiff Angled Glidewire
  • .035" x 260 Rosen

Thrombectomy Catheter: Pronto (in room) Distal Protection: 7.2mm Emboshield NAV (save introducer) Balloons:

  • 4.0 × 40 × 135 Sterling RX,
  • 5.0 × 20 x 135 Sterling RX

OR

  • 4.0 x 40 x 135 ViaTrac14,
  • 5.0 x 20 x 135 ViaTrac14

Stent: 10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician

  1. Diagnostic shots
  2. Stiff glide in diagnostic catheter
  3. Stiff glide to eca
  4. Advance diagnostic catheter to eca
  5. Exchange stiff glide for Rosen
  6. Exchange sheath for shuttle
  7. Rosen out
  8. Prep all balloons and stent and stack
  9. Prep filter
  10. Filter in
  11. Pre balloon
  12. Stent
  13. Post balloon
  14. Retrieve filter


Drugs: Atropine, Dopamine, Neosynephrine NO conscious sedation Backup Retrieval sheath: EZ bent tip 1.40mm x 150 cm Squeaky toy in opposite hand of affected side.