Difference between revisions of "St joes carotid"
From TheInterWiki
| Line 1: | Line 1: | ||
| − | ==Sheath:== | + | ==Open:== |
| + | |||
| + | ===Sheath:=== | ||
*6 Fr. Shuttle 90 cm | *6 Fr. Shuttle 90 cm | ||
**Merit touhy for shuttle (Raina) | **Merit touhy for shuttle (Raina) | ||
| − | ==Catheter:== | + | ===Catheter:=== |
*Headhunter (H1) 100 or | *Headhunter (H1) 100 or | ||
*V-tek 100cm 125 For Dr Emani | *V-tek 100cm 125 For Dr Emani | ||
| − | ==Wires:== | + | ===Wires:=== |
*.035" x 260 Angled Glidewire | *.035" x 260 Angled Glidewire | ||
*.035" x 260 Stiff Angled Glidewire | *.035" x 260 Stiff Angled Glidewire | ||
| Line 11: | Line 13: | ||
*Green torquer | *Green torquer | ||
* Extra blue stopcock so you can prep both balloons | * Extra blue stopcock so you can prep both balloons | ||
| − | ==Thrombectomy Catheter:== | + | ===Thrombectomy Catheter:=== |
*Pronto (in room) | *Pronto (in room) | ||
| − | ==Distal Protection:== | + | ===Distal Protection:=== |
*7.2mm Emboshield NAV (save introducer) | *7.2mm Emboshield NAV (save introducer) | ||
| − | ==Balloons:== | + | ===Balloons:=== |
*4.0 × 40 × 135 Sterling RX, | *4.0 × 40 × 135 Sterling RX, | ||
*5.0 × 20 x 135 Sterling RX | *5.0 × 20 x 135 Sterling RX | ||
| Line 23: | Line 25: | ||
*4.0 x 40 x 135 ViaTrac14, | *4.0 x 40 x 135 ViaTrac14, | ||
*5.0 x 20 x 135 ViaTrac14 | *5.0 x 20 x 135 ViaTrac14 | ||
| − | ==Stent:== | + | ===Stent:=== |
*10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician | *10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician | ||
| + | ==Procedure:== | ||
#Diagnostic shots | #Diagnostic shots | ||
#Stiff glide in diagnostic catheter | #Stiff glide in diagnostic catheter | ||
Latest revision as of 21:03, 14 August 2026
Open:
Sheath:
- 6 Fr. Shuttle 90 cm
- Merit touhy for shuttle (Raina)
Catheter:
- Headhunter (H1) 100 or
- V-tek 100cm 125 For Dr Emani
Wires:
- .035" x 260 Angled Glidewire
- .035" x 260 Stiff Angled Glidewire
- .035" x 260 Rosen
- Green torquer
- Extra blue stopcock so you can prep both balloons
Thrombectomy Catheter:
- Pronto (in room)
Distal Protection:
- 7.2mm Emboshield NAV (save introducer)
Balloons:
- 4.0 × 40 × 135 Sterling RX,
- 5.0 × 20 x 135 Sterling RX
OR
- 4.0 x 40 x 135 ViaTrac14,
- 5.0 x 20 x 135 ViaTrac14
Stent:
- 10-8 × 40 self-expanding (Xact or Abbott) or size appropriate per physician
Procedure:
- Diagnostic shots
- Stiff glide in diagnostic catheter
- Stiff glide to eca
- Advance diagnostic catheter to eca
- Exchange stiff glide for Rosen
- Exchange sheath for shuttle
- Rosen out
- Prep all balloons and stent and stack
- Prep filter
- Filter in
- Pre balloon
- Stent
- Post balloon
- Retrieve filter
Drugs: Atropine, Dopamine, Neosynephrine
NO conscious sedation
Backup Retrieval sheath: EZ bent tip 1.40mm x 150 cm
Squeaky toy in opposite hand of affected side.